Button Load Cell
Button Load Cells are strain gage based transducers with temperature compensation and excellent overall performance. This type provides a range of capacities up to 150 kN or 30 klb with better than ±0.5% (full scale) non-linearity. Three tapped holes are provided on the underside for ease of mounting. Fully welded cover, amplified and digitised versions are available on request.
Model number: ALBM
For more information or to request additional specification, please contact us.
Why Choose HITEC Sensors?
- Tailored Solutions: We specialize in customizing sensors to meet your specific needs, ensuring the perfect fit for your application.
- Comprehensive Warranty: Enjoy peace of mind with our standard 12-month warranty on all products.
- Recalibration Services: Maintain accuracy and reliability with our professional recalibration services.
- Efficient Lead Times: Benefit from lead times as quick as 2 weeks. Contact us for precise details.
Specifications
Product Specifications
Parameter | Range | Notes |
Capacity (metric) | 100, 200, 500, 1000, 2000, 5k, 10k, 15k, 20k, 50k, 100k, 150k N | With metric threads as standard |
Capacity (lb) | 25, 50, 100, 250, 500, 1000, 2000, 3k, 4k, 5k, 7.5k, 10k, 15k, 20k, 30k lb | With UNF threads as standard |
Rated Output (RO) | 2mV/V Nominal (1mV/V for 100N and 25lb.) | Amplified and digitised versions available to order. |
Non-linearity | ±0.5% FS MAX | |
Hysteresis | ±0.3% FS MAX | |
Repeatability | ±0.1% FS MAX | |
Zero balance | 2% FS MAX | 10% FS MAX for welded version |
Temp Shift Zero | 0.01% FS/°C | |
Temp Shift Span | 0.02% FS/°C | |
Compensated Temp Range | -15 °C TO 70 °C | Wider range available to order |
Operating Temp Range | -20 °C TO 80 °C | Wider range available to order |
IP Rating | IP64 – Bonded Cover, IP66 – Bonded Cover | Bonded cover is standard. Welded cover available to order. |
Bridge resistance | 350 Ohms Nominal for 100-500N & 25-100lb., 700 Ohms Nominal for 1kN & 250lb. | |
Excitation | 5V Recommended, 10V Max | |
Safe overload | 150% F.S. | |
Total error | ±0.8% FS MAX | Non-linearity and hysteresis |
TEDS | IEEE1451.4 TEDS | Optional |
Resources
Technical Bulletins
File
button_load_cell_hds_albm_060421_15.2.pdf