press-force-load-cell-dsc_0013

Press Force Load Cell

Press Force Load Cells are strain gauge based transducers for press-force monitoring. This type offers capacities up to 100 kN with compensated temperature performances. Cable is contained within a stainless steel spring for strain relief purposes for additional protection.

Model number: PFLC

For more information or to request additional specification, please contact us.

    Specifications
    Capacity (kN) 2, 5, 10, 20, 50 and 100  
    Capacity (klbf) 0.5, 1, 2, 5, 10 and 20  
    Rated Output (RO) 1 mV/V +/- 20% Voltage, current loop and digital output versions are available on request
    Non-linearity +/- 0.25% FS +/- 0.5% FS MAX
    Hysteresis +/- 0.25% FS +/- 0.5% FS MAX
    Repeatability +/- 0.1% FS MAX  
    Zero balance +/- 2% RO +/- 5% for welded versions
    Temp Shift Zero 0.02% RO/°C  
    Temp Shift Span 0.02% RO/°C  
    Compensated Temp Range -15°C TO 70°C  
    Operating Temp Range -40°C TO 70°C  
    IP Rating IP60 IP67 for welded version
    Bridge resistance 700Ω  
    Excitation 2-12 Vdc  
    Safe overload 200% FS No influence on measurement
    Material Stainless steel  
    Ultimate load > 300% FS  
    TEDS IEEE1451.4 TEDS Optional